Report – Coal – Exposure to irrespirable atmospheres – September 2025 to April 2026
This report provides the findings of an assessment program at underground coal mines focussing on the ventilation control plan
| Sector | Coal – underground |
|---|---|
| Principal control plan | Ventilation control plan |
| Material unwanted event | Exposure to irrespirable atmospheres |
| Topic | Coal-UG-exposure to irrespirable atmospheres |
Operation type assessed
| Operation type | Number of mines assessed |
|---|---|
| Underground | 17 |
| Total | 17 |
Criteria assessed
| Critical control | Criteria |
|---|---|
| Mine Design to manage contaminant generation and/or interaction with contaminants to within safe limits |
Has the mine executed their design to minimise generation and interaction with irrespirable conditions, including:
|
| Workers restricted / removed from areas with irrespirable atmospheres |
Are personnel aware of the techniques to restrict or remove personnel from areas with irrespirable atmospheres, including:
Is there evidence these are being implemented effectively on site? Can personnel on site correctly identify irrespirable or unsafe atmospheric conditions? |
| Ventilation flow rates controlled to remove or minimise contaminants | Verify ventilation flowrates throughout the mine. Does it match the designed flowrates? |
| Pre-drainage and gas drainage (irrespirable gas reduction) | Is gas drainage being conducted as per design? |
Findings with issues identified – underground mines
| Critical control | Criteria | Findings of concern | Findings of contravention | Total findings with issues |
|---|---|---|---|---|
| Mine Design to manage contaminant generation and/or interaction with contaminants to within safe limits |
Has the mine executed their design to minimise generation and interaction with irrespirable conditions, including:
|
1 | 0 | 1 |
| Workers restricted / removed from areas with irrespirable atmospheres |
Are personnel aware of the techniques to restrict or remove personnel from areas with irrespirable atmospheres, including:
Is there evidence these are being implemented effectively on site? |
1 | 0 | 1 |
| Can personnel on site correctly identify irrespirable or unsafe atmospheric conditions? | 1 | 0 | 1 | |
| Ventilation flow rates controlled to remove or minimise contaminants | Verify ventilation flowrates throughout the mine. Does it match the designed flowrates? | 1 | 0 | 1 |
| Pre-drainage and gas drainage (irrespirable gas reduction) | Is gas drainage being conducted as per design? | 0 | 0 | 0 |
| Total program findings with issues | 4 | 0 | 4 | |
| Other topic findings – not related to Ventilation CP irrespirable atmospheres | 9 | 4 | 13 |
Compliance notice type issued during the program
| Notice type | Notices | Percentage of all notices issued |
|---|---|---|
| WHS(MPS)A s23 notice of concerns | 11 | 73% |
| WHSA s191 improvement notice | 4 | 27% |
| WHSA s195 prohibition notice | 0 | 0% |
| Total | 15 | 100% |
A total of 15 compliance notices were issued to 8 UG coal mines
Note: This data represents all notices issued during the program and may include notices other than Ventilation CP-irrespirable atmosphere topics.
Recommendations
Operators of underground coal mines should review their site principal ventilation control plan and the critical controls assessed for the topic of exposure to irrespirable atmospheres.
| Critical control | Criteria | Recommendations to industry |
|---|---|---|
| Mine Design to manage contaminant generation and/or interaction with contaminants to within safe limits |
Has the mine executed their design to minimise generation and interaction with irrespirable conditions, including:
|
|
| Workers restricted / removed from areas with irrespirable atmospheres |
Are personnel aware of the techniques to restrict or remove personnel from areas with irrespirable atmospheres, including:
Is there evidence these are being implemented effectively on site? |
|
| Can personnel on site correctly identify irrespirable or unsafe atmospheric conditions? | Ensure workers and supervisors are trained and verified competent the in the site ventilation control plan for identification and management of irrespirable or unsafe atmospheric conditions | |
| Ventilation flow rates controlled to remove or minimise contaminants | Verify ventilation flowrates throughout the mine. Does it match the designed flowrates? | Ensure ventilation flow rates are monitored by regular inspection and reporting systems to ensure flow rates align within the ventilation design range |
| Pre-drainage and gas drainage (irrespirable gas reduction) | Is gas drainage being conducted as per design? |
|
References
Program Fact Sheet
Safety Alert
Fire occurs on longwall face in underground coal mine (PDF, 548.91 KB)
Conveyor tail pulley fire (PDF, 464.95 KB)
Safety bulletin
Methane gas incidents occurred in NSW coal mines (PDF, 185.08 KB)
Investigation information release
Outburst at NSW underground coal mine (PDF, 2.16 MB)
Regulator web resources